This centrifuge is ideal for microtube filtration and rapid centrifugation, micro-blood cell separation, microbial sample processing, for PCR, small volume cell separation, and separation of HPLC samples. It is an ideal tool for processing small batches of centrifuged samples.
Compact, fast, powerful, and affordable
THE DC permanent magnet motor, ultra-quiet
LCD LCD screen displays speed and time at the same time
Rotor replacement without any auxiliary tools, convenient and fast
Real-time monitoring of the centrifugation process to ensure the safe operation of the instrument
Resistant to various chemical corrosion, the rotor has the function of high temperature disinfection
Faster acceleration/deceleration rates required to complete experiments in less time
Multi-novel composite test tube rotor, compatible with more test tube rotors, more comprehensive functions
The air flow design also greatly reduces the heating of the sample during high-speed centrifugation
More user-friendly design, there will be a voice prompt when the operation is over, error and unbalance, and stop running at the same time, and the LCD will display the code
Product number | CF-M12 |
Speed [r/min.] | 500~12000rpm |
Relative centrifugal force [×g] | 9700×g |
Speed step increase | 500rpm |
Timing range | 1-99min./1-59sec. |
Speed deviation | ±5% |
way to control | ST16-bit MCU/PWM/speed; |
Display method | THE LCD with white characters on black background |
drive mode | THE DC Permanent Magnet Motor |
Operation method | Touch key operation |
Misoperation/fault alarm | Voice prompt + display code |
Rotor configuration | SG-B: 1.5/2.2ml×12+0.2ml×8 holes×4 rows/adapter 0.5/0.2ml×12 ( standard ) |
SG-C: PCR tube rotor 0.2ml × 12 holes × 4 rows (standard) | |
SG-D: Angle rotor 5ml×4 holes/ conical bottom tube with cover/adapter 1.8/1.1ml×4 (optional) | |
SG-E: capillary hematocrit rotor; diameter 1.5 x length 40 capillaries x 12/hematocrit rotor reading card (optional) | |
Dimensions: length × width × height [mm] | 190×230×120 |
Weight (without rotor) | 2Kg |
Noise at RPM | ≤47dB(A) |
acceleration time | ≤12s |
deceleration time | ≤16s |
Protection class | IP21 |
Allowable ambient temperature/relative humidity | 5-40℃/80% |
Power fuse | PPTC / resettable fuse / no need to replace |
input power | AC85-264V/50/60Hz |
input power | 40W |
Test standard | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61010-3-2/A2 |
Turn* | Capacity ml × number of tubes | Speed (r/min.) | Relative centrifugal force (×g) | Tube Type |
Composite rotor | 1.5/2.2×12+PCR0.2×8×4 rows | 12000 | 9700 | PP cone bottom with cover |
PCR rotor | PCR0.2×12×4 rows | 12000 | 5960 | PP cone bottom with cover |
Angle rotor | 5×4 | 12000 | 9660 | PP cone bottom with cover |
Angle rotor | Capillary hematocrit tube × 12 | 12000 | 8371 | Diameter 1.5mm×40 |
Angle rotor | 5/1.8/1.1×4 | 7000 | 3180 | PP can stand screw pipe |
SG-1 | host | |
SG-2 | 1.5/2.2ml×12+PCR0.2ml×8 wells×4 rows/adapter 0.5ml/0.2ml×12 | Standard |
SG-3 | PCR row tube rotor 0.2ml × 12 wells × 4 rows | Standard |
SG-4 | Angle rotor 5ml×4 holes/ cone bottom with cover tube /adapter 1.8/1.1ml×4 | Optional |
SG-5 | Capillary hematocrit rotor; diameter 1.5mm × length 40mm capillary × 12/hematocrit rotor reading card | Optional |